true

PowerGlide™ Midline Catheters

A fully integrated midline device designed for peripheral IV therapy to help increase both patient and clinician satisfaction

Background Image
PowerGlide™ Midline Catheters

Ready to learn more? Let’s have a conversation.

Loading
Overview

Helping to provide options for all your midline patient needs

Our goal is to provide exceptional vascular access products. We leave it up to you, the skilled clinician to choose the best device for your patients. We provide the options, you provide the expertise.

true

Industry best practice

Options to help support INS recommendations

With an ANTT insertion method, different kit configurations and added length* PowerGlide™ Pro and PowerGlide™ ST Midline Catheters provide options to achieve best practice and industry guidelines for reducing the risk of catheter failure and contamination.

These midline catheters are designed to support INS recommendations.

  • At least 2/3s of the peripheral catheter should reside within the vessel to reduce the risk of failure.1
  • Use a sterile single-use gel packet and a sterile sheath over the probe and disinfect before and after each use to reduce the risk for ultrasound probe contamination and subsequently risk for infection.1


*Compared to the similar non-reinforced tip catheters. All data on file at BD. Bench test results may not be predictive of actual clinical performance.

Advancing blood collection

Designed specifically for blood draws

Venipuncture for blood draws is one of the most performed procedures in hospitals, affecting nearly every inpatient daily.2 Choosing the right midline catheter to successfully provide treatment and blood sampling has been shown to lower the burden of blood draws for both hospitals and patients.3

This is why BD offers the PowerGlide Pro™ Midline Catheter—to help you and your team simplify insertions similar to peripheral IV catheters, with flexible placement in the lower or upper arm and catheter dwell time up to 29 days.

Reinforced tip

Designed to maintain a consistent aspiration flow rate

The reinforced tip of the PowerGlide Pro™ and PowerGlide™ ST Midline Catheters is designed to improve and maintain a consistent aspiration flow rate, without catheter collapse.*

*Compared to the similar non-reinforced tip catheters. All data on file at BD. Bench test results may not be predictive of actual clinical performance.

Reinforced tip

Designed to help overcome distal catheter tip collapse with retrograde flow during blood sampling.

Power injectable

Designed for power injection

Both PowerGlide Pro™ and PowerGlide™ ST Midline Catheters are power injectable. See each product's detail page for more information.

Please let us know the areas that you are interested in:

PowerGlide™ Midline Catheters
Ready to learn more? Let’s have a conversation.
Reference
  1. Gorski L. Infusion Therapy Standards of Practice. J Infus Nurs. 2021:44. 1S.
  2. Cadacio C. Nachamkin I. A Novel Needle-Free Blood Draw Device for Sample Collection From Short Peripheral Catheters. J Infus Nurs. 2017;40(3):156-162.doi:10.1097/NAN.0000000000000222.
  3. Penoyer D. Bennett M. Geddie PI. Nugent A. Volkerson T. CE article: evaluation of processes, outcomes, and use of midline peripheral catheters for the purpose of blood collection. J VascAccess. 2020;25(4):8-17. Doi:10.2309/JAVA-D-20-00028.
true

BD-80814 (03/24)

Overview

A fully integrated placement device designed to be a simplified solution for peripheral IV therapy.

Design innovations to enable simplified midline insertion

Click on each hot spot below to see how we have designed other components with innovations to advance insertion, blood draws and treatment success.

Home Page Image

    Needle tracking-enabled

    Supported by real-time imaging to improve insertion success


    PowerGlide Pro™ Midline Catheters are built with Cue™ Needle Tracking Technology, providing the ability to use needle tracking when paired with compatible BD ultrasound systems*. The technology provides the path, intersection point and real-time depth of the needle throughout the insertion procedure, helping you to place catheters confidently and efficiently.**

    *PowerGlide Pro™ Midline Catheters with Cue™ Needle Tracking Technology are compatible with these BD ultrasound systems:

    • Prevue™ II Peripheral Vascular Access System
    • SiteRite™ 9 Ultrasound System


    **Compared to traditional ultrasound techniques

    Power injectable

    Designed for power injection

    PowerGlide Pro™ Midline Catheters allow for the injection of contrast media for CT scans at maximum flow rates:

    • 18 G: 7 mL/sec
    • 20 G: 5 mL/sec
    • 22 G: 2 mL/sec

    Caution: When using room temperature (20°C) contrast with a 26.6 cP viscosity, maximum flow rate may not be achieved.

    Related solutions

    Kit components

    PowerGlide Pro™ Midline

    PowerGlide Pro™ Basic

    PowerGlide Pro™ FullPowerGlide Pro™ Full kit with probe coverPowerGlide Pro™ Max Barrier
    PowerGlide Pro™ Midline Catheter

    StatLock™ Stabilization Device

    Skin prep pad

    ID sticker

    Adhesive foam strips 

    Alcohol wipes 
    Absorbent drapes 
    Adhesive Foam Strips 
    Alcohol Wipes 
    Absorbent Drape 
    Fenestrated drape, full body (73 in)   
    Fenestrated drape (36 x 24 in) 
    Absorbent towel 
    Tourniquet  
    Mask, vapor barrier 
    Gloves, latex-free, purple nitrile, medium 
    Chlorhexidine Gluconate applicator (3 mL) 
    Adhesive dressing 
    Surgical tape 
    Extension set (Microbore 7 in) 
    Gauze (2 x 2 in) 
    Gauze (4 x 4 in) 
    Sterile saline 10 mL 
    PowerGlide Pro™ bedside sign with measuring tape 
    PowerGlide Pro™ patient guide 

    Bouffant cap, large   
    Lidocaine kit   
    Aspiration device (filter straw)   
    Surgical gown   
    Syringe (5 mL)   
    Safety needle hypodermic (0.5 mm, 25 G x 5/8 in)   
    BIOPATCH® dressing*option available*option available*option available 
    GuardIVa™ Antimicrobial hemostat IV dressing*option available*option available*option available 
    Probe cover (48 in)  *option available 

    Please let us know the areas that you are interested in:

    PowerGlide™ Midline Catheters
    Ready to learn more? Let’s have a conversation.

    Overview

    The PowerGlide ST™ Midline Catheter provides the clinician a PowerGlide™ Midline Catheter with the familiarity of the Seldinger placement.

    Features and benefits

    Excellent midline options for your vascular access needs

    PowerGlide™ ST Midline Catheter is designed to give you the flexibility you need according to your expertise and patient needs.

    Seldinger technique

    Pre-loaded dilator inside the catheter with over the wire placement

    Reinforced tip catheter

    Designed to improve and maintain a consistent aspiration flow rate without catheter collapse

    Unique hub design

    Allows for easy identification, helping to eliminate catheter confusion

    Power injectable

    Designed for power injection

    PowerGlide™ ST Midline Catheters allow for the injection of contrast media for CT scans at maximum flow rates:

    • 18 G: 7 mL/sec
    • 20 G: 5 mL/sec
    • 22 G: 2 mL/sec

    Caution: When using room temperature (20°C) contrast with a 26.6 cP viscosity, maximum flow rate may not be achieved.

    Related solutions

    Kit components

    PowerGlide Pro™ Midline

    PowerGlide Pro™ Basic

    PowerGlide Pro™ FullPowerGlide Pro™ Full kit with probe coverPowerGlide Pro™ Max Barrier
    PowerGlide Pro™ Midline Catheter

    StatLock™ Stabilization Device

    Skin prep pad

    ID sticker

    Adhesive foam strips 

    Alcohol wipes 
    Absorbent drapes 
    Adhesive Foam Strips 
    Alcohol Wipes 
    Absorbent Drape 
    Fenestrated drape, full body (73 in)   
    Fenestrated drape (36 x 24 in) 
    Absorbent towel 
    Tourniquet  
    Mask, vapor barrier 
    Gloves, latex-free, purple nitrile, medium 
    Chlorhexidine Gluconate applicator (3 mL) 
    Adhesive dressing 
    Surgical tape 
    Extension set (Microbore 7 in) 
    Gauze (2 x 2 in) 
    Gauze (4 x 4 in) 
    Sterile saline 10 mL 
    PowerGlide Pro™ bedside sign with measuring tape 
    PowerGlide Pro™ patient guide 

    Bouffant cap, large   
    Lidocaine kit   
    Aspiration device (filter straw)   
    Surgical gown   
    Syringe (5 mL)   
    Safety needle hypodermic (0.5 mm, 25 G x 5/8 in)   
    BIOPATCH® dressing*option available*option available*option available 
    GuardIVa™ Antimicrobial hemostat IV dressing*option available*option available*option available 
    Probe cover (48 in)  *option available 

    Please let us know the areas that you are interested in:

    PowerGlide™ Midline Catheters
    Ready to learn more? Let’s have a conversation.

    PowerGlide Pro™ Midline Catheter

    Sort by:

    PowerGlide ST™ Midline Catheter

    Sort by:

    Please let us know the areas that you are interested in:

    PowerGlide™ Midline Catheters
    Ready to learn more? Let’s have a conversation.
    Resources

    Please let us know the areas that you are interested in:

    PowerGlide™ Midline Catheters
    Ready to learn more? Let’s have a conversation.