Power-Trialysis™ Slim-Cath™ Short-Term Dialysis Catheter

The power of three: Flexibility. Utility. Reliability. Experience the difference.

Contact Us
ezgif-5-f573fbe33c.png
Loading

Overview

false
Features and Benefits

Flexibility

  • The oval catheter shaft demonstrated better kink resistance than competitive triple-lumen dialysis catheters*
  • The thermosensitive polyurethane catheter shaft provides stiffness during insertion, but softens at body temperature
  • Power-Trialysis™ Slim-Cath™ Catheter 12 Fr demonstrated ~46% smaller kink diameter than a competitor*


*As demonstrated through simulated testing. Bench test results may not necessarily be indicative of clinical performance.

Utility

  • The third power-injectable lumen is easily identifiable and provides additional access for multiple therapies
  • Multiple insertion lengths of 12.5 cm, 15 cm, 20 cm, 24 cm and 30 cm (lengths vary per catheter configuration)
  • Straight and curved catheter configurations
  • Standard kit and full max barrier tray options. 12 Fr Power-Trialysis™ Slim-Cath™

Reliability

  • Demonstrated a reliable flow rate up to 400 mL/min and recirculation of 2% on average through simulated testing*
  • Enables clinicians to facilitate compliance with federal regulations and guidelines
     

*As demonstrated through simulated testing. Results may not be indicative of actual clinical performance. Different tests may yield different results.

Additional features

  • Third purple lumen provides intravenous therapy, power injection of contrast media and central venous pressure monitoring
  • Clamps indicate priming volumes on arterial and venous ports. Third lumen priming volume is listed on the extension leg.
  • Rotatable suture wing for catheter adjustments
  • Depth markings facilitate insertion of catheter to desired depth
  • Oval catheter shaft designed for kink resistance
  • Catheter shaft comprised of thermosensitive polyurethane, which softens at body temperature, but still provides stiffness during insertion

Power-Trialysis™ Acute Dialysis Catheters Evaluation Request

Products & Accessories
Sort by:
Resources

Kit Components

DescriptionTrayKit
Catheter11
Adhesive Dressing11
Aspiration Device (Filter Straw)20
Attachable Suture Wing11
Bouffant Cap10
End Cap33
Drape, Body, Fenestrated 70 in. x 110 in.10
Dualator® Vessel Dilator 11-13 Fr.11
Dualator® Vessel Dilator 12-14 Fr.11
Gauze pad 10 cm x 10 cm (4 in. x 4 in.)60
Gloves10
Gown10
Introducer Needle, 18 Ga. x 7 cm (2.75 in.)01
Lidocaine HCI 1%, 5 ml Ampule10
Mask20
Needle Holder10
Safety Introducer Needle, 18 Ga. x 7 cm (2.75 in.)10
Safety Needle, 22 Ga. x 4 cm (1.5 in.)10
Safety Needle, 25 Ga. x 1.6 cm (0.625 in.)10
Safety Scalpel10
Sodium Chloride (Saline) 0.9% 10 ml Ampule30
StruXure™ Guidewire J-tip 70 cm x 0.89 mm (0.035 in.)11
Suture with Curved Needle10
Syringe, Luer Lock, 12 ml30
Syringe, Luer Slip, 6 ml20
Syringe, Luer Lock, 6 ml10
Frequently Asked Questions

A surgical gown.

Contrast-induced nephropathy is most commonly defined as acute renal failure occurring within 48 hours of exposure to intravascular radiographic contrast material that is not attributable to other causes.

The rate of recirculation is less than 2% on average in both the forward and reverse directions, when tested in vitro.*

It comes in both a straight and curved extension leg version, but not an Alphacurve® catheter.

The connectors for the dialysis lumens (blue and red) are acetal, the power injection lumen connector (purple), and the extension legs are polyurethane. The catheter shaft and tip are made from Thermosensitive Bodysoft polyurethane which softens at body temperature.

Up to 400 mL/min*

No, the BD repair kit is not indicated for the Power-Trialysis Slim-Cath catheter.

Each kit includes an 11–13 Fr. and a 12–14 Fr. Dualator Vessel Dilator. Two dilators are provided to progressively widen the insertion site.

The Power-Trialysis Slim-Cath catheter luer-lock is compatible with povidone iodine, and the exit site is compatible with povidone iodine, chlorhexidine gluconate 2% solution, chlorhexidine gluconate 4% solution, dilute aqueous sodium hypochlorite, hydrogen peroxide, chlorhexidine patches, and bacitracin zinc ointments in petrolatum bases.

The catheter tip must be in the lower superior vena cava for optimal performance. If placed femorally, the catheter tip should be placed in the inferior vena cava to minimize recirculation. Catheters greater than 24 cm are intended for femoral vein insertion. CAUTION: For jugular and subclavian insertion, the catheter tip should not be located in the right atrium. WARNING: Verification of the catheter tip location must be confirmed by x-ray.

The physician will determine this based on the patient needs. The Power-Trialysis Slim-Cath catheter can be used for other therapies concurrent with dialysis The third lumen is completely independent from the two dialysis lumens and is indicated for power injection of contrast media, and central venous pressure monitoring; and can be used for blood draws and medication delivery without the need for a separate access.

The third lumen should be locked per hospital protocol for central lines. The priming volume is printed on the extension leg.

The largest guidewire that may be used is a 0.035 in (0.89 mm).

The catheter shaft is oval for two reasons. First, the oval shaft improves the catheter’s kink resistance. Second, the oval shape allows for the internal kidney-shaped lumen design which provides high flow rates of 400 mL/min.

The main difference is a smaller French size. The Power-Trialysis Slim-Cath catheter is a 12 Fr. and the Power-Trialysis catheter is a 13 Fr.  

The rate of recirculation is less than 2% on average in both the forward and reverse directions, when tested in vitro.1

It comes in both the straight and a curved extension version but not an Alphacurve® catheter.

The connectors for the dialysis lumens (blue and red) are acetal, the power injection lumen connector (purple), and the extension legs are polyurethane. The catheter shaft and tip are made from Thermosensitive Bodysoft polyurethane which softens at body temperature.

Up to 400 mL/min1

No, the BD repair kit is not indicated for the Power-Trialysis Slim-Cath catheter.

Each kit includes an 11–13 Fr. and a 12–14 Fr. Dualator Vessel Dilator. Placers should dilate to the largest portion of each Dualator to allow the catheter to more easily enter the tissue and vessel. Two dilators are provided to progressively widen the insertion site.

A surgical gown.

The Power-Trialysis Slim-Cath catheter is compatible with the following agents: Povidone iodine, 0.55% sodium hypochlorite solution, chlorhexidine gluconate 4%, chlorhexidine gluconate 2% solution, dilute aqueous sodium hypochlorite, hydrogen peroxide, and bacitracin zinc ointments in petrolatum bases.

The catheter tip must be in the lower superior vena cava for optimal performance. If placed femorally, the catheter tip should be placed in the inferior vena cava to minimize recirculation. Catheters greater than 24 cm are intended for femoral vein insertion. CAUTION: For jugular and subclavian insertion, the catheter tip should not be located in the right atrium. WARNING: Verification of the catheter tip location must be confirmed by x-ray.

The physician will determine this based on the patient needs. The Power-Trialysis Slim-Cath catheter can be used for other therapies concurrent with dialysis The third lumen is completely independent from the two dialysis lumens and is indicated for power injection of contrast media, and central venous pressure monitoring; and can be used for blood draws and medication delivery without the need for a separate access.

Contrast-induced nephropathy is most commonly defined as acute renal failure occurring within 48 hours of exposure to intravascular radiographic contrast material that is not attributable to other causes.

The third lumen should be locked per hospital protocol for central lines. The priming volume is printed on the extension leg and is also available in the instructions for use (IFU).

The largest guidewire that may be used is a 0.035 in (0.89 mm).

The catheter shaft is oval for two reasons. First, the oval shaft improves the catheter’s kink resistance. Second, the oval shape allows for the internal kidney-shaped lumen design which provides high flow rates of 400 mL/min1 The wide axis of the catheter is 15 Fr., while the short axis is 10 Fr. The French size of the catheter is the average of those numbers, 12 Fr.

The main difference is a smaller French size. The Power-Trialysis Slim-Cath catheter is a 12 Fr. and the Power-Trialysis catheter is a 13 Fr. According to BD's internal market research, some physicians prefered a smaller sized catheter that could still flow at a high rate. A smaller catheter increases our product offering to accommodate varying vascular needs.

This warning was added to ensure a syringe was not used for blood infusions to prevent high pressures. Blood transfusions through a blood pump are allowed.

true
Reference

Please consult product labels and inserts for any indications, contraindications, hazards, warnings, precautions and directions for use.

*As demonstrated through simulated testing. Results may not be indicative of actual clinical performance. Different tests may yield different results.