Power-Trialysis™ Acute dialysis catheters Power-Trialysis™ Slim-Cath™ Short-Term Dialysis Catheter

Power Trialysis™ Slim-Cath™ Short-Term Dialysis Catheter, 30 cm, straight extension legs, basic kit

Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Ordering
Phone Icon
1.714.283.2228
5 a.m. to 4 p.m. PT
Fax Icon
1.714.283.8424
oem@carefusion.com
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Fax Icon
1.800.847.2220
Overview
true
Features and Benefits
Promotional Story
false
References

1. Based on simulated testing. May not be indicative of actual clinical performance. Verification Testing Competitive Comparisons, M458-034-005, 2016 , 3-point Bend Comparison Testing Performance Results, M506-013-001, 2015. BD, Inc., Salt Lake City, UT.

Please go to the product specific page to find the Safety Information link for inserts and labels, as well as indications, directions for use, contraindications, hazards, warnings, and precautions.

true
Specification

GTIN - Case

10801741107266

5

GTIN - each

00801741107269

1

GTIN - Box

20801741107263

50


Kit Configuration

Kit

Package

5 each/case


Catheter Size

12.0 Fr

Insertion Length (Tip to Cuff)

30 cm

Catheter Configuration

Straight

GTIN

GTIN - Case 10801741107266 5
GTIN - each 00801741107269 1
GTIN - Box 20801741107263 50

Packaging

Kit Configuration Kit
Package 5 each/case

Product Basic Specification

Catheter Size 12.0 Fr
Insertion Length (Tip to Cuff) 30 cm
Catheter Configuration Straight
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions

A surgical gown.

Contrast-induced nephropathy is most commonly defined as acute renal failure occurring within 48 hours of exposure to intravascular radiographic contrast material that is not attributable to other causes.

The rate of recirculation is less than 2% on average in both the forward and reverse directions, when tested in vitro.*

It comes in both a straight and curved extension leg version, but not an Alphacurve® catheter.

The connectors for the dialysis lumens (blue and red) are acetal, the power injection lumen connector (purple), and the extension legs are polyurethane. The catheter shaft and tip are made from Thermosensitive Bodysoft polyurethane which softens at body temperature.

Up to 400 mL/min*

No, the BD repair kit is not indicated for the Power-Trialysis Slim-Cath catheter.

Each kit includes an 11–13 Fr. and a 12–14 Fr. Dualator Vessel Dilator. Two dilators are provided to progressively widen the insertion site.

The Power-Trialysis Slim-Cath catheter luer-lock is compatible with povidone iodine, and the exit site is compatible with povidone iodine, chlorhexidine gluconate 2% solution, chlorhexidine gluconate 4% solution, dilute aqueous sodium hypochlorite, hydrogen peroxide, chlorhexidine patches, and bacitracin zinc ointments in petrolatum bases.

The catheter tip must be in the lower superior vena cava for optimal performance. If placed femorally, the catheter tip should be placed in the inferior vena cava to minimize recirculation. Catheters greater than 24 cm are intended for femoral vein insertion. CAUTION: For jugular and subclavian insertion, the catheter tip should not be located in the right atrium. WARNING: Verification of the catheter tip location must be confirmed by x-ray.

The physician will determine this based on the patient needs. The Power-Trialysis Slim-Cath catheter can be used for other therapies concurrent with dialysis The third lumen is completely independent from the two dialysis lumens and is indicated for power injection of contrast media, and central venous pressure monitoring; and can be used for blood draws and medication delivery without the need for a separate access.

The third lumen should be locked per hospital protocol for central lines. The priming volume is printed on the extension leg.

The largest guidewire that may be used is a 0.035 in (0.89 mm).

The catheter shaft is oval for two reasons. First, the oval shaft improves the catheter’s kink resistance. Second, the oval shape allows for the internal kidney-shaped lumen design which provides high flow rates of 400 mL/min.

The main difference is a smaller French size. The Power-Trialysis Slim-Cath catheter is a 12 Fr. and the Power-Trialysis catheter is a 13 Fr.  

The rate of recirculation is less than 2% on average in both the forward and reverse directions, when tested in vitro.1

It comes in both the straight and a curved extension version but not an Alphacurve® catheter.

The connectors for the dialysis lumens (blue and red) are acetal, the power injection lumen connector (purple), and the extension legs are polyurethane. The catheter shaft and tip are made from Thermosensitive Bodysoft polyurethane which softens at body temperature.

Up to 400 mL/min1

No, the BD repair kit is not indicated for the Power-Trialysis Slim-Cath catheter.

Each kit includes an 11–13 Fr. and a 12–14 Fr. Dualator Vessel Dilator. Placers should dilate to the largest portion of each Dualator to allow the catheter to more easily enter the tissue and vessel. Two dilators are provided to progressively widen the insertion site.

A surgical gown.

The Power-Trialysis Slim-Cath catheter is compatible with the following agents: Povidone iodine, 0.55% sodium hypochlorite solution, chlorhexidine gluconate 4%, chlorhexidine gluconate 2% solution, dilute aqueous sodium hypochlorite, hydrogen peroxide, and bacitracin zinc ointments in petrolatum bases.

The catheter tip must be in the lower superior vena cava for optimal performance. If placed femorally, the catheter tip should be placed in the inferior vena cava to minimize recirculation. Catheters greater than 24 cm are intended for femoral vein insertion. CAUTION: For jugular and subclavian insertion, the catheter tip should not be located in the right atrium. WARNING: Verification of the catheter tip location must be confirmed by x-ray.

The physician will determine this based on the patient needs. The Power-Trialysis Slim-Cath catheter can be used for other therapies concurrent with dialysis The third lumen is completely independent from the two dialysis lumens and is indicated for power injection of contrast media, and central venous pressure monitoring; and can be used for blood draws and medication delivery without the need for a separate access.

Contrast-induced nephropathy is most commonly defined as acute renal failure occurring within 48 hours of exposure to intravascular radiographic contrast material that is not attributable to other causes.

The third lumen should be locked per hospital protocol for central lines. The priming volume is printed on the extension leg and is also available in the instructions for use (IFU).

The largest guidewire that may be used is a 0.035 in (0.89 mm).

The catheter shaft is oval for two reasons. First, the oval shaft improves the catheter’s kink resistance. Second, the oval shape allows for the internal kidney-shaped lumen design which provides high flow rates of 400 mL/min1 The wide axis of the catheter is 15 Fr., while the short axis is 10 Fr. The French size of the catheter is the average of those numbers, 12 Fr.

The main difference is a smaller French size. The Power-Trialysis Slim-Cath catheter is a 12 Fr. and the Power-Trialysis catheter is a 13 Fr. According to BD's internal market research, some physicians prefered a smaller sized catheter that could still flow at a high rate. A smaller catheter increases our product offering to accommodate varying vascular needs.

This warning was added to ensure a syringe was not used for blood infusions to prevent high pressures. Blood transfusions through a blood pump are allowed.

true
References
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls