true

BD PhaSeal™ Optima system

The next-generation Closed-System Drug-Transfer Device (CSTD) from BD that advances hazardous drug protection

phaseal-optima_banner.jpg
BD PhaSeal™ Optima system

Ready to learn more? Let’s have a conversation.

Loading

Optimized with you, for you

Optimized with you, for you

The BD PhaSeal™ System pioneered the category of closed-system drug transfer devices (CSTDs) to help protect the pharmacists and clinicians who prepare and administer hazardous drugs. 20 years later, we turned to healthcare professionals like you for feedback and guidance to optimize its every component. The result is the BD PhaSeal Optima System—a next-generation, user-tested CSTD solution that advances hazardous drug safety.

With design innovations in every component

Every component of the BD PhaSeal Optima System is designed with no inlets or air exchange for airtight hazardous drug transfers. Click on each hot spot below to see how we have also optimized ease of use, ergonomics and performance.

true

Design innovations in every component

Every component of the BD PhaSeal Optima System is designed with no inlets or air exchange for airtight hazardous drug transfers. Click on each hot spot below to see how we have also optimized ease of use, ergonomics and performance.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Compatible

with ISO-compliant syringes and IV sets

Power grip and straight motion to connect

Aligned with the recommendations of the National Institute for Occupational Safety and Health (NIOSH)1

No alignment or orientation needed for connection

Ease of use helps to minimize learning curve

Proprietary protector

Designed to maximize drug extraction for each vial

Injector

Designed to prevent needle exposure and accidental needlesticks

Component design

Optimized for clinician comfort

Intuitive straight-push connection

Connects in one step, helping workflow integration

Locking Injector

Includes a locking feature that locks securely to the mated Luer device.

Ready to learn more? Let’s have a conversation.

BD PhaSeal™ Optima system
Ready to learn more? Let’s have a conversation.
References
Notes

* Within an ISO Class V environment following aseptic technique

** 2015

^ The ability to prevent microbial ingress for up to 168 hours should not be interpreted as modifying, extending or superseding a manufacturer's labeling recommendations for the storage and expiration dating of the drug vial. Refer to drug manufacturer's recommendations and USP compounding guidelines for shelf life and sterility information.

References
  1. Centers for Disease Control and Prevention (CDC). Easy Ergonomics: A Guide to Selecting Non-Powered Hand Tools. https://www.cdc.gov/niosh/docs/2004-164/pdfs/2004-164.pdf. Published August 18, 2004. Accessed September 2, 2020.
  2. BD Engineering study: Evaluation of PhaSeal Optima residual drug loss performance testing. 2017.
  3. BD Engineering study: Evaluation of PhaSeal Optima residual drug loss performance testing. 2018.
  4. Gilbar PJ, Chambers CR, Gilbar EC. Opportunities to significantly reduce expenditure associated with cancer drugs. Future Oncol.2017;13(15):1311-1322.
  5. McMichael DM, Jefferson DM, Carey ET, et al. Utility of the PhaSeal closed system drug transfer device. Am J Pharm Benefits.2011;3(1):9-16.
  6. Bendeka [prescribing information], North Wales, Pennsylvania. Teva Pharmaceuticals USA, Inc. 2018.
  7. Doxil [prescribing information], Bedford, Ohio. ALZA Corporation. 2016.
  8. Herceptin [prescribing information], South San Francisco, California. Genentech, Inc. 2017.
  9. Valstar [prescribing information], Chadds Ford, Pennsylvania. Endo Pharmaceuticals, Inc. 2017
  10. April 2018 ASP pricing file. CMS website. https://www.cms.gov/Medicare/Medicare-Fee-for-Service-Part-B-Drugs/McrPartBDrugAvgSalesPrice/2018ASPFiles.html. Accessed June 8, 2018.

BD-17517 (06/24)

Designed to address your economic concerns

Ease of use


Video Player is loading.
Current Time 0:00
/
Duration 0:00
Loaded: 0%
0:00
Stream Type LIVE
Remaining Time -0:00
 
1x
    • Chapters
    • descriptions off, selected
    • captions off, selected

        The BD PhaSeal™ Optima System is easy to use, and connects with one step

         

        The BD PhaSeal™ Optima System replaces the push-turn-push connection mechanism of the BD PhaSeal™ System with a one-step straight-push mechanism, making it easier for pharmacists and clinicians to use.

        phaseal-optima_block_201780418.png

        Minimize learning curve

         

        Designed to help minimize the learning curve with:

         
        • Intuitive one-step straight-push connection
        • No alignment or orientation needed to connect
         

        Let our trained clinical specialists help you efficiently integrate the BD PhaSeal™ Optima System into the workflow of your facility.

        Ergonomics


        phaseal-optima_block_171005.png

        Offer your pharmacists and clinicians an ergonomic CSTD solution

         

        We conducted head-to-head comparisons and asked both longstanding CSTD users and traditional technique users how we could improve our design. The feedback and validation we received guided us to optimize every component of the BD PhaSeal™ Optima System for user comfort.

        171005_InUse_admin_1a_112_Retouched_Original.png

        Align with NIOSH recommendations1

         

        • Uses a power grip and straight motion to connect and disconnect
        • Aligns with NIOSH recommendations to avoid pinch grip for hand-held tools1
         

        Our trained clinical specialists can also help train your pharmacists and clinicians in best practices for preparation and administration using the BD PhaSeal™ Optima System.

        Performance


        The BD PhaSeal™ Optima System can help you maximize drug extraction for each vial

        In a performance comparison, the BD PhaSeal™ Optima System demonstrated the lowest residual fluid loss of all four CSTDs tested.2,3* Minimizing residual fluid loss with such a CSTD may translate into a reduction in drug waste that can help optimize preparation of HDs and increase cost savings for your facility. 4,5

        *Bench test results may not be indicative of clinical results.

        F1.jpg
        × F1.jpg

        Minimizing this waste could enable hospitals and healthcare professionals to provide sufficient doses of drugs while using fewer vials, which could lead to cost savings.2 It could also help to align patient and facility expenditures on drugs more closely with the actual amount of medicine used.2

         

        phaseal-optima_block_201780418.png

        Designed to maximize performance

         
        • Prevents microbial ingress and may maintain drug vial sterility for up to 168 hours and 10 penetrations**^
        • Meets the requirements of the NIOSH IPA draft CSTD-test protocol, a robust test protocol applicable to barrier-type CSTDs**
        • Optimized spike-fluid channel and secure vial attachment
        • Engineered to common International Organization for Standardization (ISO) standards
        • Compatible and connects with ISO-compliant syringes, IV sets, luer fittings and standard-size drug vials
         

        We can share the 'Minimizing residual drug loss' and 'Assessment of microbial ingress' whitepapers with you, and help you calculate potential drug savings for your facility.


        Download Whitepaper

        Contact us to get started

        *Within an ISO Class V environment following aseptic technique. The ability to prevent microbial ingress for up to 168 hours should not be interpreted as modifying, extending or superseding a manufacturer's labeling recommendations for the storage and expiration dating of the drug vial. Refer to drug manufacturer's recommendations and USP compounding guidelines for shelf life and sterility information.

        Safety


        safty1.png

        Designed to reduce the risk of surface and environmental contamination of hazardous drugs

         

        The BD PhaSeal™ Optima System may help improve healthcare worker safety by reducing the risk of surface contamination to hazardous drugs. The BD PhaSeal™ Optima System incorporates the double membranes and vapor capture mechanisms pioneered by the BD PhaSeal™ System, which has been demonstrated to reduce the risk of hazardous drug exposure.

        The BD PhaSeal Optima System meets the NIOSH definition of a CSTD that mechanically prohibits the transfer of environmental contaminants into the system and the escape of drug vapor concentrations outside the system, thereby minimizing individual and environmental exposure to drug vapor, aerosols and spills.

        phaseal-optima_block_2011103TC5s_160.png

        Secure your Luer lock connections with the option of the N40-O locking injector

         

        • Locking feature that locks securely to the mated Luer device
        • Spinning collar enables rotation of syringe to view scale markings and prevent tangling of IV lines
        • May reduce drug leaks, large spills and waste
        • Helps prevent leaks in transport to clinical settings
        • Helps reduce risk of delays in treatment that could lead to under-dosing and patient dissatisfaction


        Download Whitepaper

        Contact us to get started
        safty3.png

        Leakproof and airtight by design

         
        • Spike design prevents vapor leakage when puncturing a vial
        • Self-sealing membranes on all components
        • Airtight drug transfers in preparation and administration
        • Leakproof for both short- and long-term connections
         

        Let our trained clinical specialists help you seamlessly upgrade your facility to the BD PhaSeal Optima System.

        Contact us to get started

        Ready to learn more? Let’s have a conversation.

        BD PhaSeal™ Optima system
        Ready to learn more? Let’s have a conversation.
        References
        Notes

        * Within an ISO Class V environment following aseptic technique

        ** 2015

        ^ The ability to prevent microbial ingress for up to 168 hours should not be interpreted as modifying, extending or superseding a manufacturer's labeling recommendations for the storage and expiration dating of the drug vial. Refer to drug manufacturer's recommendations and USP compounding guidelines for shelf life and sterility information.

        References
        1. Centers for Disease Control and Prevention (CDC). Easy Ergonomics: A Guide to Selecting Non-Powered Hand Tools. https://www.cdc.gov/niosh/docs/2004-164/pdfs/2004-164.pdf. Published August 18, 2004. Accessed September 2, 2020.
        2. BD Engineering study: Evaluation of PhaSeal Optima residual drug loss performance testing. 2017.
        3. BD Engineering study: Evaluation of PhaSeal Optima residual drug loss performance testing. 2018.
        4. Gilbar PJ, Chambers CR, Gilbar EC. Opportunities to significantly reduce expenditure associated with cancer drugs. Future Oncol.2017;13(15):1311-1322.
        5. McMichael DM, Jefferson DM, Carey ET, et al. Utility of the PhaSeal closed system drug transfer device. Am J Pharm Benefits.2011;3(1):9-16.
        6. Bendeka [prescribing information], North Wales, Pennsylvania. Teva Pharmaceuticals USA, Inc. 2018.
        7. Doxil [prescribing information], Bedford, Ohio. ALZA Corporation. 2016.
        8. Herceptin [prescribing information], South San Francisco, California. Genentech, Inc. 2017.
        9. Valstar [prescribing information], Chadds Ford, Pennsylvania. Endo Pharmaceuticals, Inc. 2017
        10. April 2018 ASP pricing file. CMS website. https://www.cms.gov/Medicare/Medicare-Fee-for-Service-Part-B-Drugs/McrPartBDrugAvgSalesPrice/2018ASPFiles.html. Accessed June 8, 2018.

        BD-17517 (06/24)

        Easy to use in the preparation and administration of hazardous drugs


        phaseal-optima_C_no-id-video-screenshot.jpg

        See how pharmacists and clinicians can implement the airtight and leakproof BD PhaSeal™ Optima System.

        Video Player is loading.
        Current Time 0:00
        /
        Duration 0:00
        Loaded: 0%
        0:00
        Stream Type LIVE
        Remaining Time -0:00
         
        1x
          • Chapters
          • descriptions off, selected
          • captions off, selected
              Preparation

              BD PhaSeal™ Optima System instructional video for preparation

              Video Player is loading.
              Current Time 0:00
              /
              Duration 0:00
              Loaded: 0%
              0:00
              Stream Type LIVE
              Remaining Time -0:00
               
              1x
                • Chapters
                • descriptions off, selected
                • captions off, selected
                    Administration

                    BD PhaSeal™ Optima System instructional video for administration

                    87034.jpg
                    And with ongoing product training and education, our trained clinical specialists can help your facility upgrade seamlessly from your current method to the BD PhaSeal™ Optima System.
                     

                    Ready to learn more? Let’s have a conversation.

                    BD PhaSeal™ Optima system
                    Ready to learn more? Let’s have a conversation.
                    References
                    Notes

                    * Within an ISO Class V environment following aseptic technique

                    ** 2015

                    ^ The ability to prevent microbial ingress for up to 168 hours should not be interpreted as modifying, extending or superseding a manufacturer's labeling recommendations for the storage and expiration dating of the drug vial. Refer to drug manufacturer's recommendations and USP compounding guidelines for shelf life and sterility information.

                    References
                    1. Centers for Disease Control and Prevention (CDC). Easy Ergonomics: A Guide to Selecting Non-Powered Hand Tools. https://www.cdc.gov/niosh/docs/2004-164/pdfs/2004-164.pdf. Published August 18, 2004. Accessed September 2, 2020.
                    2. BD Engineering study: Evaluation of PhaSeal Optima residual drug loss performance testing. 2017.
                    3. BD Engineering study: Evaluation of PhaSeal Optima residual drug loss performance testing. 2018.
                    4. Gilbar PJ, Chambers CR, Gilbar EC. Opportunities to significantly reduce expenditure associated with cancer drugs. Future Oncol.2017;13(15):1311-1322.
                    5. McMichael DM, Jefferson DM, Carey ET, et al. Utility of the PhaSeal closed system drug transfer device. Am J Pharm Benefits.2011;3(1):9-16.
                    6. Bendeka [prescribing information], North Wales, Pennsylvania. Teva Pharmaceuticals USA, Inc. 2018.
                    7. Doxil [prescribing information], Bedford, Ohio. ALZA Corporation. 2016.
                    8. Herceptin [prescribing information], South San Francisco, California. Genentech, Inc. 2017.
                    9. Valstar [prescribing information], Chadds Ford, Pennsylvania. Endo Pharmaceuticals, Inc. 2017
                    10. April 2018 ASP pricing file. CMS website. https://www.cms.gov/Medicare/Medicare-Fee-for-Service-Part-B-Drugs/McrPartBDrugAvgSalesPrice/2018ASPFiles.html. Accessed June 8, 2018.

                    BD-17517 (06/24)

                    Other products you may be interested in

                    • chemo-safety-system_banner_J8P8992.jpg

                      Protect clinicians and patients from exposure to hazardous drugs with a closed system

                    • hd-check-system.jpg

                      Get results in less than 10 minutes with the first and only rapid hazardous drug* detection system

                       

                    Resources

                    Videos

                    Ready to learn more? Let’s have a conversation.

                    BD PhaSeal™ Optima system
                    Ready to learn more? Let’s have a conversation.
                    true
                    BD PhaSeal™ Optima System BD BD PhaSeal™ Optima System /content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg

                    The next-generation Closed-System Drug-Transfer Device (CSTD) from BD that advances hazardous drug protection

                    closed system drug transfer device, CSTD, closed syringe, hazardous cstd, HDs, PhaSeal, chemo safety products, easy to use CSTD, drug transfer