true

UltraScore™ PTA-Ballon mit gebündelter Kraft

Spezial-Scoring-Ballon

4l30qzdcgtsfv35htmjbmfncq34hczcj.jpg
Wird geladen
Überblick

Merkmale

  • Specialty Scoring Balloon
  • Focused Force Dilatation
  • Low Profile, Over-the-Wire Design
  • 2 Longitudinal .010″ wires placed 180 degrees apart
  • .014″ & .035″ Compatible
  • Broadest Scoring Balloon Portfolio (up to 300mm)2
  • GeoAlign™ Marking System

 

The UltraScore™ Balloon is the first commercially available .035” scoring balloon, with sizes available on both .014” and .035” guidewire platforms.

true
Merkmale und Vorteile
Für kontrollierte Plaque-Modifizierung entwickelt

Im Vergleich zu einem Standard-PTA-Ballon derselben Größe bietet der UltraScore™ Ballon Folgendes:

  • Etwa 24-Mal mehr Kraft, wenn der Draht die Läsion zusammenzieht1
  • Ist so konzipiert, dass er die Plaque bei niedrigerem Inflationsdruck in Längsrichtung aufbricht
  • Kann einen stärker kontrollierten Plaquebruch und weniger Gefäß-Recoil ermöglichen, selbst bei kalzifizierten Läsionen
Geringes Profil, Over-the-Wire Design

Der UltraScore™ PTA-Ballon mit gebündelter Kraft ist auf einer 0,035"- und 0,014"-Plattform erhältlich und ist der Scoring-Ballonkatheter mit dem geringsten Profil auf dem US-amerikanischen Markt.2

  • Der einzige 4F-Scoring-Ballonkatheter auf dem US-amerikanischen Markt2
  • Erster kommerziell erhältlicher 0,035"-Scoring-Ballonkatheter auf dem US-Markt2
  • Hydrophile Beschichtung für optimierte Applikationsfähigkeit auf der 0,014"-Plattform
Ausgestattet mit dem GeoAlign™ Markierungssystem

Der UltraScore™ PTA-Ballon mit gebündelter Kraft ist der erste Scoring-Ballonkatheter mit dem GeoAlign™ Markierungssystem zur Verwendung als intravaskuläres Messinstrument

  • Zur Reduzierung der Fluoroskopiezeit um bis zu 27 % in einer präklinischen Studie3
  • Einfach zu bedienendes, nicht röntgendichtes Lineal am Katheterschaft erleichtert die wiederholte Katheter- und geografische Ausrichtung3

Breitestes Portfolio von Scoring-Ballonkathetern auf dem US-Markt2

Umfangreichste Größenmatrix

  • Erster kommerziell erhältlicher 0,035"-Scoring-Ballonkatheter auf dem US-Markt
  • Weitere Größenangebote auf einem 0,014"- und 0,035" Draht4
  • Hydrophile Beschichtung für optimierte Applikationsfähigkeit auf der 0,014"-Plattform
  • Der einzige 4F-Scoring-Ballonkatheter auf dem US-amerikanischen Markt2

 

0,035"

Schaftlängen (cm)130
Ballondurchmesser (mm)54, 5, 6, 7, 8
Ballonlängen (mm)20, 40, 80, 100, 120, 150, 200, 300
Schaftkompatibilität (F)5, 6

 

0,014"

 
Schaftlängen (cm)150
Ballondurchmesser (mm)52, 2,5, 3, 3,5, 4, 5, 6, 7
Ballonlängen (mm)20, 40, 80, 100, 120, 150, 200, 300
Schaftkompatibilität (F)4, 5
Ressourcen

Literaturhinweise

1. Based on theoretical calculation using equation P=F/A comparing UltraScore™ Balloon to POBA. Data on File, Bard Peripheral Vascular, Inc., Tempe, AZ. May not be predictive of clinical performance. Different tests may yield different results.
2. As of January 2022.
3. When the catheter is introduced to the vascular system, the location of balloon should be confirmed while under fluoroscopic observation. GeoAlign™ Markers are not a replacement for fluoroscopy. Animal study (repeat PTA in swine artery) was performed by 3 physicians who tested the Lutonix™ 035 (no drug) and the Ultraverse® 035 pta Catheter, both with GeoAlign™ Markers, to POBA with no GeoAlign™ Markers(n=112, test n=96 (average placement time of 66 seconds), control n=16 (average placement of 90 seconds)). Animal data on file, Bard Peripheral Vascular, Inc. Tempe, AZ. Animal test results may not be indicative of clinical performance. Different test methods may yield different results.
4. Compared to all other scoring balloons on the U.S. Market
5. Not all diameters available in every length

Please consult Instructions for Use under Resources for product indications for use, contraindications, warnings, precautions, complications, adverse events and detailed safety information.

BD-23452v3

true
CE-numer-2797

BD-23452v3

true
UltraScore™ PTA-Ballon mit gebündelter Kraft BD Ultrascore™ Focused Force PTA-Ballon Für kontrollierte Plaque-Modifizierung entwickelt,

Im Vergleich zu einem Standard-PTA-Ballon derselben Größe bietet der UltraScore™ Ballon Folgendes:

  • Etwa 24-Mal mehr Kraft, wenn der Draht die Läsion zusammenzieht1
  • Ist so konzipiert, dass er die Plaque bei niedrigerem Inflationsdruck in Längsrichtung aufbricht
  • Kann einen stärker kontrollierten Plaquebruch und weniger Gefäß-Recoil ermöglichen, selbst bei kalzifizierten Läsionen
,Geringes Profil, Over-the-Wire Design,

Der UltraScore™ PTA-Ballon mit gebündelter Kraft ist auf einer 0,035"- und 0,014"-Plattform erhältlich und ist der Scoring-Ballonkatheter mit dem geringsten Profil auf dem US-amerikanischen Markt.2

  • Der einzige 4F-Scoring-Ballonkatheter auf dem US-amerikanischen Markt2
  • Erster kommerziell erhältlicher 0,035"-Scoring-Ballonkatheter auf dem US-Markt2
  • Hydrophile Beschichtung für optimierte Applikationsfähigkeit auf der 0,014"-Plattform
,Ausgestattet mit dem GeoAlign™ Markierungssystem,

Der UltraScore™ PTA-Ballon mit gebündelter Kraft ist der erste Scoring-Ballonkatheter mit dem GeoAlign™ Markierungssystem zur Verwendung als intravaskuläres Messinstrument

  • Zur Reduzierung der Fluoroskopiezeit um bis zu 27 % in einer präklinischen Studie3