StatLock™ IV Stabilisierungssystem für den BD Saf-T-Intima™ Katheter 

4dc247cf-873a-4711-88fb-659e35f9ba3e
Loading
Übersicht

Das erste StatLock™ Stabilisierungssystem mit vertiefter Klebeoberfläche für die Katheterflügel, das nachweislich Komplikationen reduziert und die Verweildauer verlängert.

Highlights

  • Speziell für den BD Saf–T Intima™ Katheter konstruiert.
  • Verankerungskissen aus Schaumstoff mit alkohollöslichem Kleber hilft, Hautverletzungen zu vermeiden.
  • Steril und latexfrei.
true

The first StatLock™ Stabilization Device to feature the "adhesive well" that is proven to reduce complications and increase dwell times.

Highlights

  • Custom crafted to fit BD Intima™ and BD Saf–T Intima™ catheters.
  • Anchor pad consists of closed cell foam with an alcohol soluble adhesive designed to help prevent skin injury.
  • Sterile and Latex-free.
true
Produktmerkmale

Das StatLock™ IV Stabilisierungssystem für den BD Saf-T-Intima™ Katheter verfügt über eine zusätzliche Klebeoberfläche, um den
BD Saf-T-Intima™ Katheter zu stabilisieren.

Die StatLock™ Stabilisierungssysteme sind eine effektivere Alternative zu Klebestreifen und tragen zur Verbesserung der klinischen Ergebnisse, der Behandlungsqualität und der wirtschaftlichen Effizienz bei.1

Products & Accessories
RELATED PRODUCTS NOT AVAILABLE
References
false
Weiterführende Informationen
Frequently Asked Questions

Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.

While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.

You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.

BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.

When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.

Yes.

  • Always orient the push-tab straight up.
  • Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.
  • The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.

You can use them to:

  • Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub
  • Fashion a J-loop with the IV tubing
  • Form a cushion under your luer lock spin nut
  • For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security
  • Reinforce the StatLock stabilization devices. They are sterile, tape is not.

If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.

StatLock IV Ultra stabilization device

With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.

StatLock IV Select stabilization device

For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.

<p>Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.</p> <p>While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.</p>

<p>You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.</p> <p>BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.</p> <p>When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.</p>

<p>Yes.</p> <li>Always orient the push-tab straight up.</li> <li>Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.</li> <li>The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.</li>

<p>You can use them to:</p> <li>Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub</li> <li>Fashion a J-loop with the IV tubing</li> <li>Form a cushion under your luer lock spin nut</li> <li>For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security</li> <li>Reinforce the StatLock stabilization devices. They are sterile, tape is not.</li>

<p>If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.</p> <p><strong>StatLock IV Ultra stabilization device</strong></p> <p>With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.</p> <p><strong>StatLock IV Select stabilization device</strong></p> <p>For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.</p>

true

Referenzen

Bitte beachten Sie, dass möglicherweise nicht alle Produkte, Dienstleistungen oder Merkmale von Produkten und Dienstleistungen in Ihrer Region verfügbar sind. Bitte erkundigen Sie sich bei Ihrem BD Außendienstmitarbeiter vor Ort.

  1. Schears, G.J., Summary of product trials for 10, 164 patients: comparing an intravenous stabilizing device to tape. J InfusNurs, 2006. 29(4): S. 225-31.

Die Produktetiketten, Gebrauchsanleitungen und Packungsbeilagen enthalten Angaben zu Indikationen, Kontraindikationen, Gefahren, Warnhinweisen, Vorsichtsmaßnahmen und Anleitungen zum Gebrauch.

BD-94102

true
StatLock™ IV Stabilisierungssystem für BD Intima™ Katheter BD StatLock™ IV Stabilisierungssystem für BD Intima™ Katheter ,

Das StatLock™ IV Stabilisierungssystem für den BD Saf-T-Intima™ Katheter verfügt über eine zusätzliche Klebeoberfläche, um den
BD Saf-T-Intima™ Katheter zu stabilisieren.

,,

Die StatLock™ Stabilisierungssysteme sind eine effektivere Alternative zu Klebestreifen und tragen zur Verbesserung der klinischen Ergebnisse, der Behandlungsqualität und der wirtschaftlichen Effizienz bei.1

/content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg