true
{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
StatLock™ StatLock™ Arterial Plus Stabilization Device

StatLock™ Arterial Stabilization Device, Crescent

Icon to close the modal
Support
Customer Care & Ordering
Phone Icon
866 979 9408, (905 288 6000 non toll free)
Modal Close Icon
Contact Us
Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Overview
  • The color-coded red retainer, designed for patient safety, is the most sophisticated StatLock® Stabilization Device retainer ever.
  • Unique entry angle of retainer is designed to prevent catheter kinking, which could lead to occlusion.
  • The precision molded, ergonomic retainer can be opened and closed while in place, allowing for tubeset changes whenever necessary.
  • The StatLock® Arterial Plus Stabilization Device fits adult and pediatric (over 18 months) patients.
  • Breathable anchor pad made from nonabsorbent tricot polyester.
  • Sterile, DEHP-free and latex-free.
true
Features and Benefits
Promotional Story
false
Specification

GTIN - each

00801741083044

1

GTIN - Box

20801741083048

250

GTIN - Case

10801741083041

25


Natural Latex

No


Quantity

25/case

Stand Alone or Kit

Stand Alone

GTIN

GTIN - each 00801741083044 1
GTIN - Box 20801741083048 250
GTIN - Case 10801741083041 25

FDA, Premarket Approval, and Regulatory

Natural Latex No

Packaging

Quantity 25/case
Stand Alone or Kit Stand Alone
Electronic Instructions for Use (eIFUs)
Resources
Frequently Asked Questions

Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.

While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.

You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.

BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.

When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.

Yes.

  • Always orient the push-tab straight up.
  • Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.
  • The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.

You can use them to:

  • Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub
  • Fashion a J-loop with the IV tubing
  • Form a cushion under your luer lock spin nut
  • For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security
  • Reinforce the StatLock stabilization devices. They are sterile, tape is not.

If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.

StatLock IV Ultra stabilization device

With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.

StatLock IV Select stabilization device

For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.

<p>Nearly.The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or tapes.</p> <p>While the StatLock stabilization device is probably appropriate for more than 99% of your patients; some people have skin that simply will not accept an adhesive-based product – their skin is too flaky, too greasy, or too diaphoretic. Use clinical judgment. Just know that where you can use StatLock stabilization device, your clinical and cost outcomes will be dramatically improved.</p>

<p>You do need to extend your insertion site alcohol prep or chlorhexidine prep widely to both sides to cover the securement site. This is a necessary step to cleanse the skin before the StatLock stabilization device application.</p> <p>BD recommends the use of the skin prep pad included with the StatLock stabilization device. The skin prep provides an acrylic layer that protects the skin and enhances adherence of the anchor pad. Performing both of these steps will maximize product performance.</p> <p>When you use the skin prep you'll need to allow it to dry for 10 to 15 seconds and make certain it is dry, meaning smooth to the touch – not tacky. Use your clinical judgment based on assessment of the patient's skin. Just remember, when skin prep is not used the StatLock stabilization devices may prematurely lift.</p>

<p>Yes.</p> <li>Always orient the push-tab straight up.</li> <li>Always connect the StatLock stabilization retainer device to the PIV before placing the StatLock stabilization device onto skin.</li> <li>The blue StatLock stabilization device retainer clip is like an upside-down "V". Therefore, do not inadvertently squeeze it closed by compressing both sides. Instead, just hold one side and snap it over the hub of the catheter.</li>

<p>You can use them to:</p> <li>Stabilize the catheter while prepping and securing with the StatLock stabilization device by applying the foam strips over the catheter hub</li> <li>Fashion a J-loop with the IV tubing</li> <li>Form a cushion under your luer lock spin nut</li> <li>For extension sets without luer locks, wrap them around the catheter and the extension set connection for added security</li> <li>Reinforce the StatLock stabilization devices. They are sterile, tape is not.</li>

<p>If you had a tape-secured PIV, then you would have to remove the tape to change the tubing.</p> <p><strong>StatLock IV Ultra stabilization device</strong></p> <p>With the StatLock IV Ultra stabilization device you can keep the stabilization device in place while you change tubing. Simply steady the retainer with the thumb and index finger of one hand while unscrewing the extension set. Remove the set. Then, while continuing to brace the retainer, press-fit and screw in your replacement extension set.</p> <p><strong>StatLock IV Select stabilization device</strong></p> <p>For StatLock IV Select stabilization device, you will need to replace the StatLock stabilization devices when you remove and replace the tubing – just as you would with tape securement; but this is a rare event offset by StatLock stabilization device advantages.</p>

true
Related Products
RELATED PRODUCTS NOT AVAILABLE
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
References

Specifications subject to change without notice.

Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.

true
true