Ballonnet pour ATP avec application d’une force ciblée UltraScore™

Ballonnet d’évaluation spécial

4l30qzdcgtsfv35htmjbmfncq34hczcj.jpg
Chargement
Présentation

Caractéristiques

  • Specialty Scoring Balloon
  • Focused Force Dilatation
  • Low Profile, Over-the-Wire Design
  • 2 Longitudinal .010″ wires placed 180 degrees apart
  • .014″ & .035″ Compatible
  • Broadest Scoring Balloon Portfolio (up to 300mm)2
  • GeoAlign™ Marking System

 

The UltraScore™ Balloon is the first commercially available .035” scoring balloon, with sizes available on both .014” and .035” guidewire platforms.

true
Caractéristiques et avantages
Conçu pour la modification contrôlée des plaques

Par rapport à un ballonnet pour ATP standard de la même taille, UltraScore™ :

  • Exerce une force environ 24 fois supérieure là où le fil contracte la lésion1
  • Est conçu pour fracturer la plaque dans le sens longitudinal à une pression de gonflage plus faible
  • Peut permettre une fracture de la plaque mieux contrôlée et moins de recul des vaisseaux, même dans les lésions calcifiées
Conception Over-the-Wire de petite taille

Le ballonnet pour ATP avec application d’une force ciblée UltraScore™ est disponible sur une plate-forme de 0,035" et 0,014". Il s’agit du plus petit ballonnet d’évaluation disponible sur le marché américain.2

  • Seul ballonnet d’évaluation 4F disponible aux États-Unis2
  • Premier ballonnet d’évaluation de 0,035" disponible dans le commerce aux États-Unis2
  • Revêtement hydrophile pour une facilité de navigation optimisée sur une plate-forme de 0,014"
Intègre le système de graduation GeoAlign™

Le ballonnet pour ATP avec application d’une force ciblée UltraScore™ est le premier ballonnet d’évaluation à comporter le système de graduation GeoAlign™ destiné à être utilisé comme outil de mesure intravasculaire

  • Conçu pour réduire le temps de radioscopie, de jusqu’à 27 % dans une étude préclinique3
  • La règle non radio-opaque simple à utiliser présente sur le corps du cathéter permet de répéter facilement le positionnement du cathéter et l’alignement géographique.3

Gamme de ballonnets d’évaluation la plus vaste du marché américain2

Grand choix de tailles de matrices

  • Premier ballonnet d’évaluation de 0,035" disponible dans le commerce aux États-Unis
  • Offre d’autres tailles sur fil de 0,014" et 0,035"4
  • Revêtement hydrophile pour une facilité de navigation optimisée sur une plate-forme de 0,014"
  • Seul ballonnet d’évaluation 4F disponible aux États-Unis2

 

0,035"

Longueurs du corps (cm)130
Diamètres du ballonnet (mm)54, 5, 6, 7, 8
Longueurs du ballonnet (mm)20, 40, 80, 100, 120, 150, 200, 300
Compatibilité du corps (F)5,6

 

0,014"

 
Longueurs du corps (cm)150
Diamètres du ballonnet (mm)52, 2.5, 3, 3.5, 4, 5, 6, 7
Longueurs du ballonnet (mm)20, 40, 80, 100, 120, 150, 200, 300
Compatibilité du corps (F)4,5

Références

1. Based on theoretical calculation using equation P=F/A comparing UltraScore™ Balloon to POBA. Data on File, Bard Peripheral Vascular, Inc., Tempe, AZ. May not be predictive of clinical performance. Different tests may yield different results.
2. As of January 2022.
3. When the catheter is introduced to the vascular system, the location of balloon should be confirmed while under fluoroscopic observation. GeoAlign™ Markers are not a replacement for fluoroscopy. Animal study (repeat PTA in swine artery) was performed by 3 physicians who tested the Lutonix™ 035 (no drug) and the Ultraverse® 035 pta Catheter, both with GeoAlign™ Markers, to POBA with no GeoAlign™ Markers(n=112, test n=96 (average placement time of 66 seconds), control n=16 (average placement of 90 seconds)). Animal data on file, Bard Peripheral Vascular, Inc. Tempe, AZ. Animal test results may not be indicative of clinical performance. Different test methods may yield different results.
4. Compared to all other scoring balloons on the U.S. Market
5. Not all diameters available in every length

Please consult Instructions for Use under Resources for product indications for use, contraindications, warnings, precautions, complications, adverse events and detailed safety information.

BD-23452v3

true
true
Ballonnet pour ATP avec application d’une force ciblée UltraScore™ BD Ballonnet pour ATP avec application d’une force ciblée Ultrascore™ Conçu pour la modification contrôlée des plaques,

Par rapport à un ballonnet pour ATP standard de la même taille, UltraScore™ :

  • Exerce une force environ 24 fois supérieure là où le fil contracte la lésion1
  • Est conçu pour fracturer la plaque dans le sens longitudinal à une pression de gonflage plus faible
  • Peut permettre une fracture de la plaque mieux contrôlée et moins de recul des vaisseaux, même dans les lésions calcifiées
,Conception Over-the-Wire de petite taille,

Le ballonnet pour ATP avec application d’une force ciblée UltraScore™ est disponible sur une plate-forme de 0,035" et 0,014". Il s’agit du plus petit ballonnet d’évaluation disponible sur le marché américain.2

  • Seul ballonnet d’évaluation 4F disponible aux États-Unis2
  • Premier ballonnet d’évaluation de 0,035" disponible dans le commerce aux États-Unis2
  • Revêtement hydrophile pour une facilité de navigation optimisée sur une plate-forme de 0,014"
,Intègre le système de graduation GeoAlign™,

Le ballonnet pour ATP avec application d’une force ciblée UltraScore™ est le premier ballonnet d’évaluation à comporter le système de graduation GeoAlign™ destiné à être utilisé comme outil de mesure intravasculaire

  • Conçu pour réduire le temps de radioscopie, de jusqu’à 27 % dans une étude préclinique3
  • La règle non radio-opaque simple à utiliser présente sur le corps du cathéter permet de répéter facilement le positionnement du cathéter et l’alignement géographique.3