true

Dispositif de fixation permanente CapSure™  

capsure-banner-lg.jpg
Loading

Présentation

Permanent Fixation Redefined

CapSure™ provides surgeons the confidence they desire through strong and reliable fixation.

Traditional challenges in permanent fixation for hernia repair

Permanent fixation devices facilitate a strong long-term repair but may be associated with some challenges:

  • Clinical complications from exposed metal points including adhesions to fastener
  • Difficulties securing large pore mesh may impact hernia repair outcomes
  • Deployment challenges and device reliability issues can disrupt procedures


BD has redefined permanent fixation

Covered

  • Smooth polyetheretherketone (PEEK) cap eliminates exposed metal tip and helps minimize adhesions to the fastener*


Strong

  • Fixates into Cooper’s ligament and underlying structures, similar to ProTack™


Reliable

  • Comfortable handle and easy to deploy trigger
  • Consistent fastener deployment and depth of tissue purchase
  • Reliable, secure fixation regardless of mesh pore size
  • Improved fixation with large pore meshes due to larger cap surface area of fastener versus ProTack™

*Preclinical data. Results may not correlate to the performance in humans.

true

Caractéristiques et avantages

REDEFINED FASTENER DESIGN

Les fixations permanentes Capsure™

Acier inoxydable 316L

  • L’acier inoxydable 316L est un acier inoxydable de qualité chirurgicale couramment utilisé dans les implants biomédicaux soumis à la pression, notamment les vis à os et les prothèses

Capuchon lisse en PEEK

  • Le capuchon est fabriqué en polyétheréthercétone (PEEK). Le PEEK est un polymère thermoplastique organique inerte, considéré comme un biomatériau avancé
  • Le PEEK est utilisé dans de nombreux implants médicaux, notamment les implants dentaires, les valves cardiaques et les stents, ainsi que les prothèses articulaires
DESIGNED FOR OPTIMIZED CLINICAL BENEFITS

CONÇU POUR OPTIMISER LES BÉNÉFICES CLINIQUES

Une étude d’adhérence préclinique de 90 jours a démontré une plus grande résistance avec le système de fixation CapSure™ par rapport au système de fixation ProTack™

Évaluation d’une nouvelle attache hélicoïdale permanente avec capuchon sur un modèle porcin de réparation de hernie ventrale par laparoscopie

Arnab Majumder, Mojtaba Fayezizadeh, William W. Hope,
Yuri W. Novitsky • Surgical Endoscopy April 2016

  • Couverture d’adhérence nettement inférieure
  • Plus grand pourcentage d’attaches correctement engagées
  • Meilleure intégration entre les tissus et la maille
  • Les données suggèrent que la protection des points d’attache exposés sur la surface de la maille côté viscéral par des capuchons en polymère réduit la formation d’adhérences et facilite la fixation et l’intégration de la maille


Données précliniques. Il est possible que les résultats ne correspondent pas aux performances chez l’homme.

STRONG REPAIR

RÉPARATION RÉSISTANTE

La fixation CapSure™ pénètre facilement dans le ligament de Cooper et les structures sous-jacentes, de manière équivalente à ProTack™

Equivalent Strength to ProTack™ at t0, Greater Strength Over Time

Résistance équivalente à ProTack™ à t0, supérieure au fil du temps

Les tests de résistance à l’éclatement ont démontré que, dans un modèle porcin, le renfort de paroi Ventralight™ ST fixé par CapSure™ présentait une résistance à l’éclatement supérieure (4,3 %) à t0 et une résistance à l’éclatement maximale nettement plus élevée (18,4 %) 6 semaines après l’implantation que le renfort de paroi Ventralight™ ST fixé par ProTack™ au même point chronologique (p = 0,0088).

* Tissu de la paroi abdominale porcine. Il se peut que les données chez l’animal ne correspondent pas à la performance chez l’homme
* Étude de l’implant sur 6 semaines dans un modèle porcin. Il est possible que les résultats chez l’animal ne correspondent pas aux performances chez l’homme

Reliable

Fiable

Une plus grande confiance dans les performances de dispositif de fixation

  • Système d’entraînement rotatif doté d’une poignée ergonomique et d'une gâchette conçue pour une facilité d'utilisation, avec une force de mise en place moyenne inférieure de 30 % à celle exigée par ProTack™1
  • Déploiement des attaches et profondeur de prise des tissus uniformes - les études précliniques ont démontré des résultats plus favorables en termes d’assise des attaches par rapport à ProTack™2
  • Dispositifs disponibles en configurations de 15 et 30 attaches, permettant d’importantes économies par dispositif par rapport au ProTack™, pour les réparations nécessitant 15 attaches ou moins
Other products you might be interested in
References

Please note, not all products, services or features of products and services may be available in your local area. Please check with your local BD representative.

Indications.
The CapSure™ Permanent Fixation System is indicated for the approximation of soft tissue and fixation of surgical mesh to tissues during laparoscopic surgical procedures in ventral and inguinal hernia repair.

Contraindications.

  1. This device is not intended for use except as indicated.
  2. Do not use this device where hemostasis cannot be verified visually after application.
  3. Contraindications associated with laparoscopic surgical procedures relative to mesh fixation apply, including but not limited to: fixation of vascular or neural structures and in ischemic or necrotic tissue.
  4. Carefully inspect the area in the vicinity of the tissue being fastened to avoid inadvertent penetration of underlying structures such as bone, nerves, vessels, and viscera. Use of the CapSure™ Permanent Fixation System in the close vicinity of such underlying structures is contraindicated. For reference, the length of the fastener below the fastener head is 3.2 mm, the fastener head is another 1 mm (total 4.2 mm).
  5. This device should not be used in tissues that have a direct anatomic relationship to major vascular or nerve structures. This includes the deployment of tacks in the diaphragm in the vicinity of the pericardium, aorta, or inferior vena cava during diaphragmatic hernia repair.

Warnings.

  1. The CapSure™ Permanent Fixation System is intended for Single Use Only - DO NOT RESTERILIZE. Reuse, reprocessing, resterilization or repackaging may compromise the structural integrity and/or essential material and design characteristics that are critical to the overall performance of the device and may lead to device failure which may result in injury to the patient. Reuse, reprocessing, resterilization or repackaging may also create a risk of contamination of the device and/or cause patient infection or cross infection, including, but not limited to, the transmission of infectious diseases from one patient to another. Contamination of the device may lead to injury, illness or death of the patient or end user.
  2. Do not use beyond the expiration date on the package.
  3. This product is supplied sterile. Inspect the packaging to be sure it is intact and undamaged prior to use.
  4. Verify mechanical and electrical compatibility of devices from different manufacturers prior to using them together in a procedure.
  5. Prosthetics should be evaluated for compatibility prior to use.
  6. Users should be familiar with surgical procedures and techniques involving permanent materials before employing CapSure™ Permanent Fixation System fasteners for wound closure, as the risk of wound dehiscence may vary with the site of application and the material used.
  7. As with any implant material, the presence of bacterial contamination may enhance bacterial infectivity. Accepted surgical practice must be followed with respect to drainage and closure of infected or contaminated wounds. After use, the CapSure™ Permanent Fixation System may be a potential biohazard. Handle and dispose of in accordance with any local and federal laws regarding medical waste.

Precautions.

  1. Please read all instructions before using the CapSure™ Permanent Fixation System.
  2. Only persons having adequate medical training and familiarity with surgical techniques should perform surgical procedures. Consult the medical literature relative to technique, complications and hazards prior to any surgical procedure.
  3. The CapSure™ Permanent Fixation System can be used with most 5 mm trocars. Ensure compatibility by inserting the device into the trocar prior to introduction into the patient. The CapSure™ Permanent Fixation System should enter and exit the trocar easily without excessive force. The use of too much force could damage the instrument.
  4. Adequate counter pressure should be applied on the target area. Avoid placing hand or finger directly over the area where fastener is being deployed to prevent injury.
  5. Use caution when applying the CapSure™ fastener over or in proximity to underlying bone, vessels, nerves, or viscera. The intended fixation site should be assessed to ensure that while the tissue is compressed the total distance from the surface of the tissue to any underlying structures is greater than the length of the CapSure™ fastener.
  6. Care should be taken not to use excessive counter pressure as this may damage the tissue, the material being fixated, and/or the device.
  7. If the device locks and cannot be separated from a fastener that has been deployed into mesh and/or tissue, rotate the device counterclockwise to free the fastener from the tissue and/or to free the device. If the fastener does not deploy properly, remove the device from the patient and test the device in gauze to ensure proper fastener deployment, otherwise discard the device appropriately and use a new CapSure™ Permanent Fixation System. Once proper fastener deployment is confirmed, the device may be reinserted into the patient.
  8. The safety and effectiveness of CapSure™ Permanent Fixation System have not been evaluated or established in pregnant or breast-feeding women.
  9. This device contains the following substance(s) defined as CMR 1B in a concentration above 0.1% weight by weight: Cobalt; CAS No. 7440-48-4; EC No. 231-158-0. Current scientific evidence supports that medical devices manufactured from stainless-steel alloys containing cobalt do not cause an increased risk of cancer or adverse reproductive effects. For more information, please consult the ECHA website: https://echa.europa.eu/home.

Adverse Reactions.
Adverse reactions and potential complications associated with fixation devices such as the CapSure™ Permanent Fixation System may include, but are not limited to the following: hemorrhage, pain, edema and erythema at wound site; septicemia/infection; hernia recurrence/wound dehiscence, erosion and allergic response in patients with known sensitivities to PEEK and metals contained in 316L stainless steel, including chromium, nickel, copper, and iron. Please consult product package insert for more detailed safety information and instructions for use.

References
  1. Bench top data. Results many not correlate to performance in humans.
  2. Preclinical data. Results may not correlate to performance in humans

CE 2797

BD- 51638

true

Références

Veuillez noter que certains produits, services ou caractéristiques peuvent ne pas être disponibles dans votre région. Veuillez consulter votre représentant BD local.

CE-numer-2797

Le système de fixation permanente CapSure™ est indiqué pour l’affrontement de tissus mous et la fixation d’un filet chirurgical aux tissus en chirurgie ouverte ou laparoscopique, notamment pour la réparation des hernies ventrales et inguinales. Dispositif médical de classe IIb (Dir 93/42/CEE), CE 2797 Fabricant: Davol inc. Pour un bon usage se référer à la notice d'utilisation. Edition Avril 2023.

Références

  1. Données de bancs d’essai. Il est possible que les résultats ne correspondent pas aux performances chez l’homme.
  2. Données précliniques. Il est possible que les résultats ne correspondent pas aux performances chez l’homme

BD-119807

true
Dispositif de fixation permanente CapSure™ BD Dispositif de fixation permanente CapSure™

Les fixations permanentes Capsure™

,

Acier inoxydable 316L

  • L’acier inoxydable 316L est un acier inoxydable de qualité chirurgicale couramment utilisé dans les implants biomédicaux soumis à la pression, notamment les vis à os et les prothèses

Capuchon lisse en PEEK

  • Le capuchon est fabriqué en polyétheréthercétone (PEEK). Le PEEK est un polymère thermoplastique organique inerte, considéré comme un biomatériau avancé
  • Le PEEK est utilisé dans de nombreux implants médicaux, notamment les implants dentaires, les valves cardiaques et les stents, ainsi que les prothèses articulaires
,

CONÇU POUR OPTIMISER LES BÉNÉFICES CLINIQUES

,

Une étude d’adhérence préclinique de 90 jours a démontré une plus grande résistance avec le système de fixation CapSure™ par rapport au système de fixation ProTack™

Évaluation d’une nouvelle attache hélicoïdale permanente avec capuchon sur un modèle porcin de réparation de hernie ventrale par laparoscopie

Arnab Majumder, Mojtaba Fayezizadeh, William W. Hope,
Yuri W. Novitsky • Surgical Endoscopy April 2016

  • Couverture d’adhérence nettement inférieure
  • Plus grand pourcentage d’attaches correctement engagées
  • Meilleure intégration entre les tissus et la maille
  • Les données suggèrent que la protection des points d’attache exposés sur la surface de la maille côté viscéral par des capuchons en polymère réduit la formation d’adhérences et facilite la fixation et l’intégration de la maille


Données précliniques. Il est possible que les résultats ne correspondent pas aux performances chez l’homme.

,

RÉPARATION RÉSISTANTE

,

La fixation CapSure™ pénètre facilement dans le ligament de Cooper et les structures sous-jacentes, de manière équivalente à ProTack™

,

Résistance équivalente à ProTack™ à t0, supérieure au fil du temps

,

Les tests de résistance à l’éclatement ont démontré que, dans un modèle porcin, le renfort de paroi Ventralight™ ST fixé par CapSure™ présentait une résistance à l’éclatement supérieure (4,3 %) à t0 et une résistance à l’éclatement maximale nettement plus élevée (18,4 %) 6 semaines après l’implantation que le renfort de paroi Ventralight™ ST fixé par ProTack™ au même point chronologique (p = 0,0088).

* Tissu de la paroi abdominale porcine. Il se peut que les données chez l’animal ne correspondent pas à la performance chez l’homme
* Étude de l’implant sur 6 semaines dans un modèle porcin. Il est possible que les résultats chez l’animal ne correspondent pas aux performances chez l’homme

,

Fiable

,

Une plus grande confiance dans les performances de dispositif de fixation

  • Système d’entraînement rotatif doté d’une poignée ergonomique et d'une gâchette conçue pour une facilité d'utilisation, avec une force de mise en place moyenne inférieure de 30 % à celle exigée par ProTack™1
  • Déploiement des attaches et profondeur de prise des tissus uniformes - les études précliniques ont démontré des résultats plus favorables en termes d’assise des attaches par rapport à ProTack™2
  • Dispositifs disponibles en configurations de 15 et 30 attaches, permettant d’importantes économies par dispositif par rapport au ProTack™, pour les réparations nécessitant 15 attaches ou moins
/content/dam/bd-assets/bd-com/en-us/logos/bd/header-bd-logo.svg
capsure permanent fixation system (10 AMS), capsure device hernia (10 AMS), capsure (590 AMS)