true
{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
Ventrio™ Renforts de paroi synthétiques Patch pour hernie Ventrio™

Implant pour hernie Ventrio™

Icon to close the modal
Soutien
Service à la clientèle et commande
Icône Téléphone
866 979 9408, (905 288 6000 non toll free)
Icône Fermer le modal
Nous contacter
Icône pour fermer le modal merci
Merci d'avoir contacté notre équipe commerciale!
Un représentant commercial vous contactera sous peu
Présentation

Easy. Efficient. Proven.

The Ventrio™ Hernia Patch’s unique design and technique offer patients the benefits of an intraabdominal repair, while offering surgeons the ease of an open anterior approach, with the added ability to use mechanical fixation. The parietal side is constructed of two layers of monofilament polypropylene mesh, providing rapid tissue ingrowth and strong incorporation into the abdominal wall. The visceral side is made of submicronic ePTFE, which provides a permanent barrier minimizing tissue attachment.1

true
Caractéristiques et avantages
Notre Histoire
false
Spécification

GTIN - null

00801741016387

1


Quantité

1/cs


Dimensions

Petit ovale avec ePTFE 3,1" x 4,7" (8cm x 12cm)

GTIN

GTIN - null 00801741016387 1

Emballage

Quantité 1/cs

Spécifications du produit

Dimensions Petit ovale avec ePTFE 3,1" x 4,7" (8cm x 12cm)
Ressources
Questions fréquentes
false
Produits connexes
Produits connexes non disponibles
Plaintes concernant un produit
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Élements à prendre en compte

Si vous êtes un patient ou un utilisateur final, vous pouvez nous contacter vous-même, ou vous pouvez demander à votre soignant ou à votre médecin de le faire pour vous. Pour nous aider à traiter vos
informations rapidement et efficacement, veuillez contacter notre équipe chargée des réclamations clients.

Pour faciliter notre enquête, veuillez inclure les informations suivantes dans votre rapport:


  • Nom du produit et/ou numéro de catalogue
  • Numéro de lot ou numéro de série
  • Blessures et/ou préjudices?
  • Quel est le problème que vous avez rencontré?
  • Est-ce-que l'échantillon réel ou le représentant de l'échantillon est disponible? (Si possible, veuillez envoyer l'échantillon concerné)
  • Nom et numéro de téléphone de la personne à contacter
Références

1 Data generated in preclinical model. Data may not correlate to performance in humans.

2 Majercik, S. et al. “Strength in tissue attachment to mesh after ventral hernia repair with synthetic composite mesh in a porcine model.” Surg Endosc (2006) 20: 1671-1674.

INDICATIONS

The Ventrio™ Hernia Patch is indicated for use in the reconstruction of soft tissue deficiencies, such as for the repair of hernias.

CONTRADICTIONS

Literature reports that there may be a possibility for adhesion formation when the polypropylene is placed in contact with the bowel or viscera.

WARNINGS

1. Do not cut or reshape the Ventrio™ Hernia Patch, as this could affect its effectiveness. Care should be taken not to cut or nick the SorbaFlex™ PDO monofilament. If the SorbaFlex™ PDO monofilament is cut or damaged during insertion or fixation, additional complications may include bowel or skin perforation and infection.

2. Follow proper folding techniques for all patches as described in the Instructions for Use as other folding techniques may compromise the SorbaFlex™ PDO monofilament.

3. Ensure proper orientation; the solid white surface (ePTFE) must be oriented against the bowel or sensitive organs. Do not place the mesh surface against the bowel. There may be a possibility for adhesion formation when mesh is placed in direct contact with the bowel or viscera.

ADVERSE REACTIONS

Possible complications include seroma, adhesions, hematomas, inflammation, extrusion, fistula formation, infection, allergic reaction, and recurrence of the hernia or soft tissue defect. If theSorbaFlex™ PDO monofilament is cut or damaged during insertion or fixation, additional complications may include bowel or skin perforation and infection.

Please consult package insert for more detailed safety information and instructions for use.

BD-16948

true
true