Icon to close the modal
Support
Sales
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Modal Close Icon

Capability:

Product Line:

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Ordering
Phone Icon
1.714.283.2228
5 a.m. to 4 p.m. PT
Fax Icon
1.714.283.8424
oem@carefusion.com
Customer Service
Phone Icon
1.844.8.BD.LIFE (1.844.823.5433)
Fax Icon
1.800.847.2220

BD Insyte™ Autoguard™ shielded IV catheter

Advance safety at the push of a button

Contact Us
insyte-autoguard-catheter_RC_MMS_VA_1016-0004
Loading
Overview

The well-established BD Insyte™ Autoguard™ shielded IV catheter incorporates advanced safety features including a push button that instantly retracts the needle, helping reduce the risk of accidental needlestick injuries. It also features notched needle technology that lets you easily visualize blood return along the catheter shaft, which can enhance care for fragile vessels or vessels without venous tone.

true
Features and Benefits
Enhanced Safety

BD push-button needle shielding technology is demonstrated to reduce needlestick injuries by 95%.1*

First-Stick Success
BD Instaflash™ needle technology on 20-G, 22-G and 24-G products incorporate a notched needle, which may improve first-stick success and reduce painful hit-and-miss insertions.
Minimized Phlebitis

BD Vialon™ biomaterial softens up to 70% in the vein, enabling longer dwell times2† and reducing the chance of mechanical phlebitis by up to 50%.2†

Reference

Notes

* Compared to a nonsafety IV catheter

† Compared to a fluorinated ethylene propylene (FEP) catheter

References

1. Mendelson MH, Lin-Chen BY, Finkelstein-Blond L, et al. Evaluation of a safety IV catheter (IVC) (Becton Dickinson, Insyte Autoguard): final report (abstract). Presented at: Eleventh Annual Scientific Meeting Society for Healthcare Epidemiology of America; 2001.

2. Maki DG, Ringer M. Risk factors for infusion-related phlebitis with small peripheral venous catheters. Ann Intern Med. 1991;114:845-854.

true
Products & Accessories
RELATED PRODUCTS NOT AVAILABLE
References

Notes

* Compared to a nonsafety IV catheter

† Compared to a fluorinated ethylene propylene (FEP) catheter

References

1. Mendelson MH, Lin-Chen BY, Finkelstein-Blond L, et al. Evaluation of a safety IV catheter (IVC) (Becton Dickinson, Insyte Autoguard): final report (abstract). Presented at: Eleventh Annual Scientific Meeting Society for Healthcare Epidemiology of America; 2001.

2. Maki DG, Ringer M. Risk factors for infusion-related phlebitis with small peripheral venous catheters. Ann Intern Med. 1991;114:845-854.

true
Resources
References

Notes

* Compared to a nonsafety IV catheter

† Compared to a fluorinated ethylene propylene (FEP) catheter

References

1. Mendelson MH, Lin-Chen BY, Finkelstein-Blond L, et al. Evaluation of a safety IV catheter (IVC) (Becton Dickinson, Insyte Autoguard): final report (abstract). Presented at: Eleventh Annual Scientific Meeting Society for Healthcare Epidemiology of America; 2001.

2. Maki DG, Ringer M. Risk factors for infusion-related phlebitis with small peripheral venous catheters. Ann Intern Med. 1991;114:845-854.

true
true